HydroCalculator
São Luiz do Tapajós, Itaituba, Pará, Brazil
River: Tapajós
6,138 MW capacity
Status: Proposed project
Thales Oliveira Rosa (staff) - Mar 2nd, 2012
78 thousand hectares flooded
13 hectares per MW
977 people displaced
0 people per MW
-5,041 million BRL
net present value
(Excluding environmental costs)
Enable javascript to view charts.
| Net Present Value | -5,041 million BRL |
|---|---|
| NPV including net greenhouse gas emissions | -5,552 million BRL |
| Internal Rate of Return | 3.11% |
| Hectares flooded per MW | 13 hectares per MW |
| Gross CO₂ equivalent emissions | 479,040 thousand metric tonnes |
| Gross CO₂ equivalent per MW | 78,045 metric tonnes per MW |
| Hectares flooded per MW | 13 hectares per MW |
| People displaced per megawatt | 0 people per MW |
| People displaced | 977 people displaced |
|---|---|
| Area flooded | 78,481 hectares |
| Installed capacity | 6,138 MW |
| Capacity used | 60% |
| Construction time | 5 years |
| Construction cost | 9,200,000,000 BRL |
| Transmission infrastructure cost | 0 BRL |
| Wholesale price of energy | 24 BRL |
| Economic discount rate | 10.5% |
HydroCalculator Tool Help
- How to estimate the number of displaced people
- Wholesale price of energy
- Compare impacts to other dams
- Capacity used
- Vegetation types & biomass
- Key assumptions and how the HydroCalculator works
- Discount rate
- Transmission infrastructure cost
- Construction cost
- Construction time
- Installed capacity
- Energy Mix Graphics
- Emissions Graphics
- How to use the HydroCalculator Tool
CSF e-newsletter
I want to know the latest conservation news, and hear about upcoming CSF projects and courses.
Upcoming CSF Courses
CSF offers training in economic tools to empower local conservation organizations, decision-makers, and communities.
Outils Économiques pour la Conservation et la Planification d’Infrastructures dans le Rift Albertin
Monday, 17 June, 2013 - Friday, 28 June, 2013
Economic Tools for Conservation - 2013 International Course
Monday, 12 August, 2013 - Friday, 23 August, 2013
Comments
A capacidade utilizada foi estimada em 60%, não existe esta informação disponível.
O leilão deste empreendimento acontecera entre os anos de 2012 e 2013.
O preço da energia: foi realizada uma média do preço de venda de energia ao distribuidor no ano de 2011. O preço da energia só pode ser afirmado após o resultado do leilão, que leva em conta aquela empresa que da o menor lance no valor do preço da energia.
http://www.eln.gov.br/opencms/opencms/modulos/noticia/noticia_0479.html?...
http://www.internationalrivers.org/am%C3%A9rica-latina/os-rios-da-amaz%C...
http://www.dams-info.org/pt/dams/view/sao-luiz-do-tapajos/
Post new comment